- Type of chemical substance (agent) is a non-foaming product.
- Change to a chemical substance of the correct sort.
- Incorrect foam nozzle mounted.
- Mount original foam nozzle.
- Incorrect air pressure or incorrect air setting.
- Min. air pressure : 6 bar; 240 nl/min required.